UPGRADING THE RHODUL OUTDOOR HOUSING 8200-0324-01, REV. A
SERVICE GUIDE
1 of 9
Upgrading the RHODUL
Outdoor Housing
Service Guide
CAUTION: Read ALL
instructions carefully. Skipping
steps can compromise the
upgrade.
RHODUL-01/-02
Housing*
RHODUL-03/-04
Housing with Pigtail
(current models including
vandal resistant versions)*
Contents
About this Guide .................................................... 1
Parts Supplied .......................................................1
Tools Required ......................................................1
Identifying Issues ................................................... 2
RHODUL-01/-02 Housing ......................................3
RHODUL-03/-04 Housing ......................................4
Appendix A: Detaching and
Reattaching Bubble and Camera .......................... 6
Appendix B: Detaching and Reattaching
Environmental PC board and Cables and
Upgrading the Mounting Base ............................... 7
Appendix C: Disassembling and
Reassembling the Strain Relief Assembly
(RHODUL-01/-02 only) .......................................... 9
Appendix D: Testing Camera Function................. 9
* Identified by manufacturing label inside housing.
© Sensormatic 2003
About this Guide
This guide:
· Identifies issues that can allow water to enter
the outdoor housing
· Provides procedures for correcting problems
· Provides appendices that explain in further
detail how to correctly assemble and
disassemble the housing.
Note: Condensation may be reduced by following
instructions within this guide and observing the
following cautions.
CAUTION: Even small leaks must be
prevented as they can increase humidity
inside the housing.
DO NOT use over seals such as RTV
and silicone caulks. Housing requires an
air path through the mount to prevent
condensation.
Ensure fans spin when power is on.
If possible, mount the housing so the
least needed view (such as a wall,
building corner, or pole) is opposite the
fan/heater assembly.
Parts Supplied
Install Kit 0352-0160-01 contains:
Plug, Hex Head, 1/8in. NPT, Brass* 1 1417-0052-01
Plug, Foam, Outdoor** 1 0505-0296-01
Gasket** 1 0505-0198-01
O-ring, 3.00 ID x 3.25 OD x .125W** 1 2500-0022-05
Sleeve** 1 0500-9682-01
Filter, Foam** 1 0500-9877-01
Base, Ultra 1 0500-7257-02
* RHODUL-01/-02 only. ** RHODUL-03/-04 only.
Tools Required
· Teflon tape
· 13mm open end box wrench to remove breather
· 11mm open end box wrench to install brass plug
(RHODUL-01/-02 only)
· 10mm open end box wrench to tighten nuts at the
top of the housing
· 5.5mm nut driver for changing the mounting base
· 3mm Allen wrench to adjust setcrews securing the
housing to the mounting structure (all housings), or
end cap to the mounting structure (RHODUL-03/-04
only).
Commenti su questo manuale